• Models
  • Contests
  • Slicer
  • Login
  • Start Here
    thingiverse-iconprintables-iconcults3d-iconmakerworld-iconmyminifactory-icon

    3D GO

    3D ModelsContestsCollectionsSaved ModelsOn a mobile device?

3D GO

Privacy Policy
XL Filament Sensor Relocation Mount 3D Printer File Image 1
XL Filament Sensor Relocation Mount 3D Printer File Image 2
XL Filament Sensor Relocation Mount 3D Printer File Image 3
XL Filament Sensor Relocation Mount 3D Printer File Image 4
XL Filament Sensor Relocation Mount 3D Printer File Thumbnail 1
XL Filament Sensor Relocation Mount 3D Printer File Thumbnail 2
XL Filament Sensor Relocation Mount 3D Printer File Thumbnail 3
XL Filament Sensor Relocation Mount 3D Printer File Thumbnail 4

XL Filament Sensor Relocation Mount

OctopusRift avatarOctopusRift

November 28, 2025

printables-icon
DescriptionCommentsTags

Description

This is a wall mount for the Prusa XL filament sensors. It was created in 5 minutes by modifying another user's model to have proper senor orientation so that they would function. This can easily be modified to use less material and speed up the print process.

I used an M3x20mm and nut. The stock one will work but the longer one makes it easier to tread the nut.

Note that 4 & 5 will need to be located on the left wall and 1-3 will need to be on the right wall. Run new PTFE tubes from the sensor all the way to to the Nextruders. 

This modification will require you to extend the lengths of the cables going to the filament sensors by designing an extension or cutting and soldering to add length. I accomplished this by cutting the existing cables and soldering on additional length. Be sure to cut only a single wire at a time to avoid crossing wires. Heat shrink each splice and wrap the bundle.

11/26/25 - Added a 101mm version to get the mount farther from the wall. Also note that the mount for the 3 spool side needs to be installed about 6" farther way from the spools than shown in the photo. Having it too close makes it hard for the printer to retract and may lead to filament breaks.

Instructions to make an extension cable with connectors can be found here (note that I was unable to calibrate sensors when rotated 90 degrees as on the model below; however I did utilize his model to adapt to this one:
https://www.printables.com/model/802662-xl-filament-sensor-wire-extension-method-relocatio

Additional forum thread with connector discussion: 
https://forum.prusa3d.com/forum/original-prusa-xl-tool-changer-user-mods-octoprint-enclosures-nozzles/connector-type-filament-sensors/

Heat Rod: https://www.amazon.com/dp/B0D9QF22MY
Humidity Controller: https://www.amazon.com/dp/B0D2WW9ZN8

 

License:

Creative Commons — Attribution

Related Models

#3DBenchy - The jolly 3D printing torture-test by CreativeTools.se preview image

#3DBenchy - The jolly 3D printing torture-test by CreativeTools.se

CreativeTools profile image

CreativeTools

90,928

Important information sign for 3D printers / Wichtiges Hinweisschild für 3D-Drucker :) preview image

Important information sign for 3D printers / Wichtiges Hinweisschild für 3D-Drucker :)

Pat_S profile image

Pat_S

3d Printer Printing 3d Printer preview image

3d Printer Printing 3d Printer

JAJMWHungFamily profile image

JAJMWHungFamily

927

Self-Watering Planter (Small) preview image

Self-Watering Planter (Small)

parallelgoods profile image

parallelgoods

73,165

X, Y and Z calibration tool for IDEX / dual extruder / dual color 3D printers preview image

X, Y and Z calibration tool for IDEX / dual extruder / dual color 3D printers

Voxel3D_NL profile image

Voxel3D_NL

205

sign: don't touch my 3d printer preview image

sign: don't touch my 3d printer

Izzodesign74 profile image

Izzodesign74

631

All In One 3D Printer test preview image

All In One 3D Printer test

majda107 profile image

majda107

64,515

axes calibrage cube-xyz for 3d printers preview image

axes calibrage cube-xyz for 3d printers

H- printed profile image

H- printed

9

7