There was always a problem with the measuring system on my lathe (Sieg SC2 by Paulimot, Germany): the battery was always empty. This is because the switch for the measuring system only switches off the LCD display, but the measuring system itself always draws power. So I added this little improvement: All power is now switched off using the toggle switch. To do this, of course, it is necessary to interrupt the power supply to the board. This power supply must be interrupted very carefully with a cutter knife or a Dremel. A little bit of manual skill is necessary, but anyone who can operate a lathe will certainly have no problems here. Have fun with this little improvement.